Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (95)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (186)
- (1)
- (3)
- (22)
- (77)
- (175)
- (51)
- (43)
- (81)
- (1)
- (1)
- (45)
- (14)
- (94)
- (18)
- (1)
- (6)
- (6)
- (22)
- (26)
- (5)
- (1)
- (4)
- (3)
- (4)
- (4)
- (10)
- (16)
- (7)
- (54)
- (151)
- (59)
- (2)
- (39)
- (228)
- (45)
- (17)
- (25)
- (8)
- (109)
- (31)
- (18)
- (51)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (1)
- (15)
- (1)
- (6)
- (25)
- (27)
- (1)
- (1)
- (2)
- (79)
- (5)
- (1)
- (1)
- (1)
- (36)
- (1)
- (1)
- (793)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (376)
- (309)
- (6)
- (2)
- (3)
- (131)
- (619)
- (59)
Filtered Search Results
Spectrum™ Spectra Mesh™ Woven, Nylon Filters
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Consist of individual strands woven into a mesh screen
| Material | Nylon |
|---|
Cytiva Whatman™ Nuclepore Hydrophilic Membrane
Nuclepore track-etched hydrophilic membranes with highly defined pore size cutoff in sub-micron range
| Type | Nuclepore hydrophilic membrane |
|---|---|
| Material | Polycarbonate |
| For Use With (Application) | Bioassays, Cell biology, Environmental analysis, Microscopy, Cytology, Parasitology, Certain air and oceanography analyses |
| Pore Size | 5 μm |
|---|---|
| Bubble Point | ≥0.2 bar, air with water |
| Flow Rate | >15.4 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | PVDF |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophilic |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Cytiva Whatman™ Anodisc™ Filter Membranes
Constructed with precision pore structure and narrow pore size distribution. Whatman™ Anodisc™ Filter Membranes ensure a high level of particle removal efficiency. Captures microorganisms and particulates on the surface of the membrane for subsequent analysis.
| Material | Aluminum Oxide |
|---|
Cytiva Whatman™ Nylon Membrane Circle
For filtering aqueous solutions and most organic solvents
GVS Polycarbonate Track Etched (PCTE) Membrane, Hydrophilic, Disc, 20 μm
GVS Polycarbonate Track Etched (PCTE) Membranes are hydrophilic or hydrophobic and available in pore sizes from 0.01 to 20 μm.
| Pore Size | 20 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Material | PCTE |
| Filter Type | Microporous Filter |
| Sterility | Non-sterile |
GVS PreSep™ Glass Fiber Filter
Glass fiber is biologically inert, autoclavable and highly resistant to oxidizing agents and weak acids. Glass fiber can be used to extend the life of a final filter as a prefilter or they can be used alone for low cost sample clarification.
GVS Polyethersulfone (PES) Membrane, Disc
GVS Polyethersulfone (PES) Membranes are hydrophilic and available in pore sizes from 0.03 to 8.0 μm.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Material | PES |
| Filter Type | Microporous Filter |
MilliporeSigma™ Mitex™ Membrane Filters, Gridded
Unlaminated for extreme chemical or temperature conditions
| Thickness (Metric) | 125 μm |
|---|---|
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Filter Type | Screen Filter |
| For Use With (Application) | Clarification of acids, bases, and cryogenic fluids; clarification of propellants; analysis of hydraulic fluids; RNA isolation. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Membrane Type | Gridded |
Sartorius PTFE (Polytetrafluorethylene) Membrane Filters
Filter air and gasses, even at low differential pressures. Sartorius PTFE (Polytetrafluorethylene) Membrane Filters are permanently hydrophobic with low adsorption and excellent chemical compatibility. Choose from four pore sizes in a variety of diameters.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Material (Membrane) | PTFE |
| Color | White |
| Material | PTFE |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Air/gas-filtration |
| Autoclavable | Autoclavable |
Sartorius Cellulose Acetate Membrane Filters
Combines high flow rates and thermal stability with very low adsorption characteristics. Sartorius Cellulose Acetate Membrane Filters are excellently suited for use in pressure filtration devices. Non-sterile filters in a variety of diameters and pore sizes are bulk-packed to save money and space.
| Thickness (Metric) | 120 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Acetate |
| Color | White |
| Material | Cellulose Acetate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | For use in pressure filtration devices; Sterile filtration of solution. |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.45 μm
Hydrophobic membrane with laminated backing for easier handling
| Pore Size | 0.45 μm |
|---|---|
| Bubble Point | 7 psi |
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Diameter (Metric) | 47 mm |
| Color | White |
| Quantity | 100/Pk. |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Clarification of Acids, Bases and Solvents; Clarification of Alcohol Solutions; UV Spectroscopy. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 8.0 L/min/cm2 |
MilliporeSigma™ Isopore™ Membrane Filters, 0.4 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.
| Type | Filter Membranes |
|---|---|
| Material | Polycarbonate |
| Filter Type | Screen Filter |